Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Examinations of performance for utilization of radiation portal monitors in contamination inspection for motor vehicles in nuclear emergency (Contract research)

Hiraoka, Hirokazu; Komatsuzaki, Joji*; Hanaka, Norihiko*; Okamoto, Akiko; Saito, Yoshihiko*; Munakata, Masahiro; Togawa, Orihiko

JAEA-Technology 2022-003, 70 Pages, 2022/07

JAEA-Technology-2022-003.pdf:2.53MB

In contamination inspections for public in nuclear emergency, it is assumed that a large number of motor vehicles and evacuees will be inspected. At present, first measurement points of vehicles are tires and around a wiper, and they are basically inspected by persons using portable radiation surface contamination meters such as GM survey meters. However, in order to efficiently inspect contamination of vehicles, utilization of portable radiation portal monitors is being considered for the inspection. In this study, examination of performance of the portal monitor was conducted in order to obtain basic data. In this examinations, sealed radiation sources, $$^{133}$$Ba, were substituted for the contamination of Operational Intervention Level 4 (OIL4), the evaluation criteria to conduct simple decontamination in the contamination inspection. The radiation source was attached practically to a tire and around the wipers of a vehicle, and the counting rate of $$gamma$$-rays from the radiation sources was measured using the portal monitor. Three examinations were conducted: static examination with a vehicle stationary, moving examination to mock the actual inspection, and high back ground examination to investigate performance of the equipment in high back ground environment. The vehicle mainly used in the experiments was a sedan, which is generally used as standard vehicles. And, a van whose front body is like that of a bus was used at this experiment. In addition, the "Gamma Pole" manufactured by the Chiyoda Technol Corporation was used as the portal monitor. As the result, it was estimated that the case of contamination equivalent to 40,000 cpm, the default value of the OIL4, deposited on the tread on a vehicle tire, when the vehicle passes through the portal monitor at 10 km/h or less, the contamination would be detected with a probability of 99% or more. Similarly, when the contamination deposited on around the wipers and the vehicle speed is 5 km/h or less,

Oral presentation

Outline of the Emergency Preparedness Research Group and evaluation for utilization of radiation portal monitors in contamination inspection in nuclear emergency

Hiraoka, Hirokazu

no journal, , 

The author reports the outline of Emergency Preparedness Research Group and one of its research results. Utilization of radiation portal monitors are being considered for contamination inspection in nuclear emergency. In this study, the practicality of the monitor was evaluated experimentally for its utilization. It was found that contamination on the tire surface equivalent to OIL4, one of the Operational Intervention Levels (OILs), could be detected sufficiently. However, it was found that it was difficult to determine whether contamination on the tire surface and wiper areas was above or below OIL4.

Oral presentation

Study on optimization method for contamination inspection of vehicles in nuclear emergency, 1; Quick measurement by existent portable radiation portal monitors for vehicles

Hiraoka, Hirokazu; Kawasaki, Kohei*; Kimura, Masanori; Togawa, Orihiko; Saito, Shota; Ezaki, Iwao*

no journal, , 

When the nuclear emergency occurs, inhabitants take the contamination inspection to evacuate. A large number of vehicle will come to the inspection area and make there congested. To do the quick inspection, simultaneous measurement of tires and wipers using the portable radiation portal monitors for vehicles is a key point. Consequently, we attempted the count rates obtained from tires and wipers are discriminated. First, the vehicle was driven at 5 km/h and the $$gamma$$-ray counts rate was measured by the monitor. $$^{133}$$Ba sources were attached around the tire or on the wiper and measurements were taken 30 times each. Next, discrimination conditions based on a linear function were applied to the normalized count rates, with the maximum count rate of the measured values (Net value) set to 1.0, to evaluate the discrimination accuracy between the tire and the wiper. The evaluation results showed that the pattern with the source attached around the tire correctly discriminated 29 out of 30 times, while the pattern with the source attached on the wiper correctly discriminated 20 out of 30 times. It was found that in order to improve the accuracy of discrimination, the measurement method must be improved so that there is a large difference between measured values of the tire and the wiper.

Oral presentation

Study on optimization method for contamination inspection of vehicles in nuclear emergency, 2; Confirmation of the usefulness of the new set-up for portable radiation portal monitors for vehicles

Kawasaki, Kohei*; Hiraoka, Hirokazu; Ezaki, Iwao*; Kimura, Masanori; Togawa, Orihiko; Saito, Shota

no journal, , 

Vehicles carrying evacuees during a nuclear emergency are subject to contamination inspections, and the operation of screening by measuring tires and wiper are required. The introduction of portable radiation portal monitors for vehicles is expected to be quick tire inspections, however, it is difficult to inspect the tire and the wiper at the same time, so further speeding up the inspection process is an issue. In this study, we attempted to discriminate each type of contamination by using a different the new set up of detectors for the purpose of simultaneous inspection of tires and wiper. We will report the usefulness of the new set up and the results of simulation calculations of detector response under realistic contamination assumptions.

Oral presentation

Study on optimization method for contamination inspection of vehicles in nuclear emergency, 3; Verification of discriminative ability for contamination by the new set-up for portable radiation portal monitors for vehicles

Hiraoka, Hirokazu; Kawasaki, Kohei*; Kimura, Masanori; Togawa, Orihiko; Saito, Shota; Ezaki, Iwao*

no journal, , 

In nuclear emergency, vehicles which evacuating inhabitants use be taken the contamination inspection. For the quick inspection, it seems that realization of simultaneous inspection of tires and wipers by portable radiation portal monitors for vehicles is necessary. In order to fulfill the simultaneous inspection, the authors develop the measuring method which is able to suitably distinguish and evaluate each contamination. Monte Carlo simulation showed ahead that the new set-up of detectors improves the discriminative ability for contamination. In this study, based on the simulation results, the authors attached radiation sources to a vehicle, and verified the ability by the new-setup. As a result, the ability improved compared to one of the usual method.

Oral presentation

Study on optimization method for contamination inspection of vehicles in nuclear emergency

Hiraoka, Hirokazu

no journal, , 

In nuclear emergency, vehicles which evacuating inhabitants use be taken the contamination inspection. For the quick inspection, it seems that realization of simultaneous inspection of tires and wipers by portable radiation portal monitors for vehicles is necessary. In order to fulfill the simultaneous inspection, we develop the measuring method which is able to suitably distinguish and evaluate each contamination. We attached radiation sources to a vehicle, and verified the ability by the usual-setup and the new-setup of detectors. As a result, the ability improved compared to one of the usual-setup. We continue to improve the ability.

6 (Records 1-6 displayed on this page)
  • 1